Information
ZENworks 2017 Update 2 and above includes the ZENworks imaging engine (img) for WinPE. This enables zmg images to be restored from a WinPE environment.
NOTE: | Review the ZENworks documentation for limitations and pre-requisites. Note that existing base images captured using the Linux version of img cannot be used with WinPE. |
|
Scenario
This TID details the steps required to use the ZENworks imaging engine in the ENGL WinPE environment
NOTE: | - This TID assumes the ENGL WinPE environment has already been configured on the ZENworks server.
- ZENworks Third Party Imaging configuration is not required to use with the solution in this TID.
|
|
Procedure
WARNING! | Changes should be tested in a non-production environment and all files backed up before making any alterations. |
|
Replace zim.cfg
- Rename the existing <TFTP Folder>\zimfiles\zim.cfg
- Copy the zim.cfg attached to this TID to <TFTP Folder>\zimfiles
Copy ZENworks imaging engine files
- Create the following folder structure in the ZENworks TFTP folder
\3PIUtils
\x64
\x86
- Navigate to
<ZENworks Installation Path>\share\tomcat\webapps\zenworks\ext\3PIUtils
on the ZCM primary server - Within the
3PIUtils
folder there is a set of files and an x86_64
subfolder: - Copy the contents of the
x86_64
folder to <TFTP Folder>\3PIUtils\x64
- Copy the files within the 3PIUtils folder to
<TFTP Folder>\3PIUtils\x86
Update zimpeget.cmd script
Test
The project should deploy and build as normal using the ZENworks imaging engine rather than ENGL WinPE imaging.
If there are issues with the process review both the zim.log and zoolkit.log to troubleshoot the problem. For more information about the log files review ENGL TID-2013016
To test the changes made above complete the following steps:
- PXE boot a workstation into WinPE imaging
- Select a project to restore
- Check workstation has built as expected
If you have any problems or questions about the steps in this TID please contact the ENGL support team